Processing Machinery 3 Aufrufe

LLDPE film bubble cooling internal cooling

Problembeschreibung
Output constrained by cooling capacity; obvious improvement after adding an internal cooling system.
Ursachenanalyse
External cooling is insufficient at high LLDPE output; the IBC internal cooling system dissipates heat from inside the bubble, significantly improving cooling efficiency.; During on-site troubleshooting, verify item by item according to this mechanism, avoiding blindly adjusting the machine based only on experience.
Lösung
①Evaluate installing an IBC internal cooling system; ②match internal and external cooling balance; ③monitor bubble temperature; ④optimize air ring coordination.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability.
Wichtigste Erkenntnis
Internal cooling is standard technology for high-output LLDPE; the internal-external cooling balance determines final capacity.; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence.
LLDPE; film; internal cooling; IBC; cooling; output