Problembeschreibung
Equipment matching.
Ursachenanalyse
Match injection volume and residence; conventional machines can satisfy.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience; This mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Lösung
①Injection volume 20~80%; ②check clamping; ③stabilize process; ④regular calibration.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Wichtigste Erkenntnis
PA12 processing equipment requirements are mild.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; Include this case in the defect archive as a troubleshooting reference for subsequent similar problems