Processing Machinery 5 Aufrufe

PC Electrical Insulation Applications

Problembeschreibung
[Problem Phenomenon] Electrical insulation parts require high CTI and heat resistance
Ursachenanalyse
PC has good electrical insulation and relatively high CTI, used for electrical insulation parts and connectors; flame retardant grades are superimposed; heat resistance adapts to temperature rise; when troubleshooting on site, verify each item according to this mechanism one by one, and avoid blindly adjusting the machine based on experience alone
Lösung
Select PC for insulation parts; CTI according to voltage level; select flame retardant grades for flame retardant requirements; after adjustment, take samples continuously to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes, so as to locate effective measures
Wichtigste Erkenntnis
PC has good electrical insulation; CTI and flame retardancy are selected as needed; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future