Injection Molding
5 Aufrufe
POM '2079851475616104452 flash
Problembeschreibung
Flash at the parting line.
Ursachenanalyse
POM melt has low viscosity and easily seeps into gaps; high pressure and insufficient clamping.
Lösung
①Reduce pressure; ②calculate clamping force; ③repair mating surfaces.
Wichtigste Erkenntnis
Flash of low-viscosity material = pressure and gaps.
War das hilfreich?
0 Personen fanden dies hilfreich