Problembeschreibung
Medical PVC granules processed under ordinary conditions fail biocompatibility
Ursachenanalyse
Medical grade has special requirements for the additive system and processing temperature, and ordinary conditions destroy compliance; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based only on experience
Lösung
Medical grade follows the process specified by the supplier; take the lower limit of temperature; dedicated equipment to prevent contamination; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Wichtigste Erkenntnis
Medical PVC requires dedicated process and equipment; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future