Injection Molding
2 Aufrufe
CPE '2079851475616104452 Cycle Too Long Affecting Efficiency
Problembeschreibung
The '2079851475616104452 cycle exceeds the target by more than 20%
Ursachenanalyse
Cooling time accounts for a large proportion, plasticization is insufficient, and mold opening and closing is slow
Lösung
Optimize cooling channels, increase plasticizing capacity, and speed up mold opening and closing
Wichtigste Erkenntnis
Cycle optimization is the key to increasing production and reducing cost
War das hilfreich?
0 Personen fanden dies hilfreich