Material Analysis
10 Aufrufe
HCl gas concentration exceeds standard during processing
Problembeschreibung
Workshop HCl concentration exceeds safety standard
Ursachenanalyse
Insufficient ventilation, decomposition produces HCl
Lösung
Strengthen exhaust ventilation, online HCl detection and alarm
Wichtigste Erkenntnis
HCl is an occupational health risk
War das hilfreich?
0 Personen fanden dies hilfreich