Material Analysis 10 Aufrufe

Fast thermal aging of PU

Problembeschreibung
After aging at 80°C for 7 days, PU product mechanical properties decrease >30%
Ursachenanalyse
PU molecular chains break and degrade under thermo-oxidation; antioxidant system imperfect, insufficient protection
Lösung
1) Improve antioxidant system 1010+168+DSTDP; 2) Select high molecular weight grade; 3) Add metal deactivator 0.05wt%
Wichtigste Erkenntnis
Thermal aging is caused by thermo-oxidation; improving the antioxidant system is key
PU thermal aging thermo-oxidation antioxidant high molecular weight