Injection Molding 4 Aufrufe

Mold wear after long-term use leads to increased product defects

Problembeschreibung
Mold wear after long-term use leads to increased product defects
Ursachenanalyse
Cavity surface wear and roughening, product surface quality declines Gate wear and enlargement, unstable injection amount Parting line wear, fit accuracy decreases, flash Guide pin and guide bushing wear, positioning accuracy decreases Cooling water channel wear, leakage or blockage
Lösung
Regularly maintain and polish the cavity surface Check and repair gate dimensions Repair parting line fit accuracy Maintain guide pins and guide bushings Clean and repair cooling water channels
Wichtigste Erkenntnis
Mold wear requires regular maintenance and repair