Injection Molding
4 Aufrufe
Mold wear after long-term use leads to increased product defects
Problembeschreibung
Mold wear after long-term use leads to increased product defects
Ursachenanalyse
Cavity surface wear and roughening, product surface quality declines
Gate wear and enlargement, unstable injection amount
Parting line wear, fit accuracy decreases, flash
Guide pin and guide bushing wear, positioning accuracy decreases
Cooling water channel wear, leakage or blockage
Lösung
Regularly maintain and polish the cavity surface
Check and repair gate dimensions
Repair parting line fit accuracy
Maintain guide pins and guide bushings
Clean and repair cooling water channels
Wichtigste Erkenntnis
Mold wear requires regular maintenance and repair
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!