Material Analysis
13 Aufrufe
Solution for insufficient lubrication of calcium-zinc stabilizer in formulation lubrication balance
Problembeschreibung
The calcium-zinc PVC system shows insufficient lubrication-related abnormalities in the formulation lubrication balance production stage, the pass rate decreases.
Ursachenanalyse
The thermal stability characteristic of calcium-zinc stabilizers produces insufficient lubrication problems under specific working conditions.
Lösung
From the formulation perspective, reduce lubrication, combined with process optimization to solve it.
Wichtigste Erkenntnis
The insufficient lubrication problem of the calcium-zinc system in the formulation lubrication balance stage requires coordinated optimization of formulation and process.
War das hilfreich?
0 Personen fanden dies hilfreich