Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Molding Process 10 Aufrufe

Sizing device failure of polyolefin plastomer extruders

Problembeschreibung
The dimensional deviation of the pipe or profile after sizing is large, and the roundness or cross-sectional shape is unqualified. Sizing device failure causes the dimensional accuracy of the product to decrease.
Ursachenanalyse
(1)The vacuum degree of the vacuum sizing sleeve is insufficient or unevenly distributed (2)The sizing sleeve is worn and the inner diameter becomes larger (3)The cooling water flow is insufficient or the temperature is too high (4)The sizing sleeve is not concentric with the die (5)There is scale or impurities on the inner wall of the sizing sleeve
Lösung
(1)Check the vacuum pump and pipeline to ensure the vacuum degree is stable at 0.04-0.08MPa (2)Check the wear of the sizing sleeve; replace it if it exceeds the tolerance (3)Increase the cooling water flow and control the water temperature at 15-25°C (4)Adjust the concentricity of the sizing sleeve and the die (5)Regularly clean the inner wall of the sizing sleeve to remove scale
Wichtigste Erkenntnis
Sizing device failure needs to be solved from three aspects: vacuum system, cooling system, and mold precision.
sizing devicevacuum degreesizing sleeve wearcooling watermold concentricity

War das hilfreich?

0 Personen fanden dies hilfreich

ChemAI