Injection Molding 10 Aufrufe

Incomplete Cleaning of PBT '2079851475616104452 Machine Barrel

Problembeschreibung
Cross-contamination occurs when switching from PBT to other materials or from other materials to PBT.
Ursachenanalyse
PBT is incompatible with other resins, and mixing produces phase separation; the residual material degrades and affects the quality of the new material.
Lösung
Use a special purging material for full cleaning; clean with staged temperatures; disassemble the nozzle to clean dead corners.
Wichtigste Erkenntnis
PBT switching requires a strict cleaning procedure.
PBTcleaningcross-contaminationpurging material