Injection Molding
10 Aufrufe
Failure of PBT Injection-Molded Parts Under Dynamic Fatigue
Problembeschreibung
PBT products undergo fatigue fracture under cyclic loading.
Ursachenanalyse
Stress concentration points initiate fatigue cracks; internal stress and notch sensitivity accelerate fatigue failure; the design stress-strain level is too high.
Lösung
Optimize the product design to reduce stress concentration; fully anneal to reduce internal stress; increase the safety factor.
Wichtigste Erkenntnis
PBT fatigue performance is a key consideration for electrical switches and structural parts.