Injection Molding
3 Aufrufe
PETG '2079851475616104452 jetting marks near the gate
Problembeschreibung
Snakeskin-like or twisted jetting flow marks appear near the gate of PETG injection molded products.
Ursachenanalyse
Gate size too small, the melt enters the cavity in a jet, injection speed too fast, melt temperature low.
Lösung
Increase the gate size; reduce injection speed using multi-stage injection; appropriately increase the melt temperature.
Wichtigste Erkenntnis
PETG jetting marks are a manifestation of unstable filling flow.