Molds & Tooling 4 조회수

LCP Dimensional Anisotropy Out of Tolerance

문제 현상
Products produced in the same mold with different gate positions have different dimensions, and parts qualified in single-axis measurement are out of tolerance when measured in another direction.
원인 분석
LCP shrinkage is near zero in the flow direction while transverse shrinkage is significant; a single average shrinkage cannot predict dimensions in all directions, and different gate positions in the cavity produce different orientation patterns.
해결 방법
①Design cavity dimensions differentiated by direction; ②perform full-direction dimensional verification on first article; ③fix gate position and process; ④use mold flow analysis to assist in predicting dimensions in each direction.
핵심 요약
LCP mold shrinkage allowance must be directional; full-direction first article inspection is the standard process for LCP mold acceptance.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
LCP;dimension;anisotropy;shrinkage;shrinkage allowance;first article