메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Molding Process 4 조회수

LCP Holding Switchover Point Drift Affects Weight

문제 현상
【Problem Phenomenon】Product weight fluctuates with the holding switchover position, and dimensions drift accordingly
원인 분석
LCP's rapid crystallization makes the effective holding window extremely narrow; a slight deviation of the switchover point amplifies the compensation difference into weight and dimensions; precision parts have high requirements for switchover repeatability
해결 방법
Precisely control holding switchover by position or cavity pressure; determine the optimal switchover point by short shot test; monitor switchover repeatability and include it in equipment spot checks; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
핵심 요약
Fast crystallization makes LCP's holding window narrow; switchover precision directly determines weight stability; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
holding switchover weight fluctuation short shot test precision part

이 정보가 도움이 되었나요?