메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Injection Molding 6 조회수

PA6 '2079851475616104452 Multi-cavity Imbalance

문제 현상
Differences between cavities, inconsistent weight and dimensions.
원인 분석
Unbalanced runners and cooling differences; PA6 is sensitive to pressure and temperature, and differences between cavities are amplified; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience.
해결 방법
①Make runners geometrically balanced with equal length and diameter, or adopt a naturally balanced layout;②test with the short shot method;③check and balance the cooling water channel flow of each cavity;④when necessary, independent throttling/sequential control of each hot runner gate;⑤establish cavity number traceability and SPC to facilitate locating problem cavities.
핵심 요약
PA6 multi-cavity = 'balance test': the hardware balance of runners and cooling is fundamental; test filling balance first, then talk about the process window; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence.
PA6; multi-cavity; runner balance; cooling

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI