메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Material Drying 7 조회수

PA66 radiator water tank

문제 현상
The radiator water tank cracks after long-term immersion in coolant
원인 분석
High-temperature ethylene glycol coolant causes PA66 hydrolysis and glass fiber interface erosion, and strength decays year by year; during on-site troubleshooting, verify item by item according to this mechanism, avoiding blindly adjusting the machine based only on experience
해결 방법
Select hydrolysis-resistant reinforced special grades; verify by long-term immersion in 135℃ coolant; reserve corrosion allowance for water tank wall thickness; after adjustment, take continuous samples to verify the effect, confirm stability before resuming mass production
핵심 요약
Water tank material selection is based on hydrolysis-resistant grades plus long-term medium verification; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
PA66radiator water tankhydrolysis resistanceethylene glycol

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI