Processing Machinery
3 조회수
PA66 fan shroud
문제 현상
Cooling fan shroud fixing ears break during vibration testing
원인 분석
The shroud is excited by engine vibration, stress concentrates at the fixing ear root, and fatigue accumulates to fracture; during on-site troubleshooting, verify item by item according to this mechanism, avoiding blindly adjusting the machine based only on experience
해결 방법
Add fillets and reinforcing ribs at fixing ear roots; select fatigue-resistant reinforced grades; verify according to random vibration spectrum; after adjustment, take continuous samples to verify the effect, confirm stability before resuming mass production
핵심 요약
Vibration part fixing structures are designed and verified according to fatigue spectrum; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems