Material Analysis
12 조회수
PA66 recycled material thermal history
문제 현상
After blending recycled material, strength decreases and color difference is obvious, and performance falls off a cliff after multiple cycles
원인 분석
PA66 molecular weight decreases with each thermal history experienced, and oxidation and contamination of recycled material superimpose; after multiple cycles, impact and tensile properties deteriorate cliff-like, and appearance color difference amplifies synchronously
해결 방법
①Control recycled material ratio within 20%; ②Test melt index and mechanical properties by batch; ③Restrict or prohibit recycled material for load-bearing parts and appearance parts; after adjustment, take continuous samples to verify the effect, confirm stability before resuming mass production
핵심 요약
PA66 recycled material value decreases with thermal history; ratio, detection, and use grading are the three iron rules of recycled use; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다