PA6 Mold Temperature Controller Selection

문제 현상
Using a water temperature controller to control PA6 mold temperature cannot reach the required 90°C, and the product surface and dimensions are unstable
원인 분석
The upper limit of an atmospheric water temperature controller is about 95°C and the actual water supply temperature is even lower; the 60-90°C mold temperature required by PA6 is at the edge of equipment capability, and large temperature fluctuations cause process instability
해결 방법
When the mold temperature requirement is above 80°C, select an oil temperature controller or a pressurized water temperature controller with a control accuracy of ±1°C; the mold water circuit ensures sufficient flow, and the inlet-outlet water temperature difference is controlled within 5°C
핵심 요약
Mold temperature equipment capability must have margin; the oil temperature controller is a safe choice for PA6 high mold temperature occasions; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence
PA6mold temperature controlleroil temperature controllertemperature control accuracy