메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Molds & Tooling 3 조회수

PA6 First Article Temperature Confirmation

문제 현상
Producing immediately after start-up, the first few shots are unstable in both dimensions and appearance
원인 분석
At start-up, the barrel and mold temperatures have not yet reached equilibrium, the melt temperature and mold temperature are in the ramping stage, and process condition fluctuations cause unstable product quality; when troubleshooting on site, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
해결 방법
Run idle for 10-15 minutes after start-up until the temperature balances, and inject only after confirming that the actual measured melt temperature and cavity surface temperature meet the standards; mass produce after the first article is fully dimensionally confirmed according to the inspection specification
핵심 요약
Temperature equilibrium is the threshold for start-up quality, and first article confirmation is irreplaceable; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
PA6first articletemperature equilibriumstart-up

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI