Material Drying
4 조회수
PA6 Cable Tie Selection
문제 현상
Outdoor equipment cable ties brittlely fracture and fail in less than a year
원인 분석
Outdoor ultraviolet and dry-wet cycling accelerate PA6 aging; at dry-state low temperature, cable ties are notch-sensitive and brittlely fracture, and ordinary natural-colored material has insufficient weather resistance; when troubleshooting on site, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
해결 방법
Select carbon black UV-resistant grades for outdoor cable ties; select toughened grades for low-temperature environments; replace with PA66 or metal cable ties for high bundling force occasions; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
핵심 요약
Cable tie failure is mostly aging brittle fracture, and outdoor and low-temperature use requires dedicated selection; after confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!