Processing Machinery
3 조회수
PA6 Warpage Deformation Countermeasures
문제 현상
PA6 flat products warp to one side after ejection, and the dimensions cannot be assembled
원인 분석
PA6 has large crystallization shrinkage, and when cooling is uneven, the shrinkage difference between the two sides produces warpage; the shrinkage difference in the glass fiber orientation direction is the main cause of warpage in reinforced grades; during on-site troubleshooting, verify item by item according to this mechanism, avoiding blind machine adjustment based only on experience
해결 방법
Balance the mold cooling channels to minimize the temperature difference between the two sides; adjust the gate position to make the flow symmetric; use multi-point gates for glass fiber material to reduce orientation; use a shaping fixture to assist cooling if necessary
핵심 요약
Warpage treatment prioritizes balancing cooling and flow, and fixture shaping is a remedial means; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!