메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Extrusion & Post 10 조회수

Delamination and Peeling of PE Injection Molded Products

문제 현상
The surface of PE products peels off in layers, obvious at edges or near the gate.
원인 분석
Mixing in incompatible materials (foreign resins, contaminated regrind, color masterbatch with mismatched carrier) prevents the layers from fusing; excessive release agent forms an isolation layer on the surface; excessive gate shear causes a huge orientation difference between the skin and core layers — all three cause delamination and peeling.
해결 방법
①Investigate mixed-material contamination and standardize regrind management; ②Purge the machine thoroughly when changing material; ③Control release agent dosage; ④Reduce gate shear; ⑤Increase mold temperature to ease orientation.
핵심 요약
PE delamination = a 'contamination and compatibility' problem: first check mixed material and regrind, then control release agent and shear; for delaminated parts, don't forcibly adjust the process — find the contamination source first.
PE;delamination;contamination;compatibility;release agent

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI