Processing Machinery
3 조회수
PEI Check Valve and Clearance
문제 현상
PEI metering is unstable with melt backflow; the check valve type and screw clearance are improperly configured, and product weight fluctuates.
원인 분석
The PEI check valve should be of the sliding check ring type; the flow clearance in the screw metering zone should account for at least 80% of the cross-section of the flow area; improper configuration causes metering inaccuracy; high-viscosity melt has high sealing requirements.
해결 방법
①Select a sliding check ring type check valve; ②metering zone flow clearance ≥80% of the cross-section; ③regularly check check valve wear; ④perform metering stability spot checks.
핵심 요약
PEI check valve selection has clear type requirements; 80% flow clearance is the design standard; wear checks ensure metering stability.; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!