Material Drying
3 조회수
PLA Anti-rehumidification After Drying
문제 현상
Properly dried PLA re-absorbs moisture during conveying and in the hopper, and the extruded product performance fluctuates
원인 분석
PLA absorbs moisture quickly; dried material exposed to air rapidly re-absorbs moisture; connecting the drying hopper directly to the extruder with nitrogen sealing can control the moisture content increment within 5ppm
해결 방법
①Connect the drying hopper directly to the extruder to shorten exposure; ②Nitrogen sealing to prevent rehumidification; ③Moisture content increment <5ppm as the acceptance index of the feeding system; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
핵심 요약
PLA anti-rehumidification requires accounting for the increment; direct connection plus nitrogen sealing makes the 5ppm increment the design index of the feeding system; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!