Molding Process
11 조회수
PMMA Continuous Load Limit
문제 현상
PMMA structural parts creep and deform under long-term load, eventually failing by stress cracking
원인 분석
PMMA continuous load should not exceed 600psi (about 4.1MPa) at 23℃; long-term action beyond this limit will cause stress cracking and eventual failure, and structural design often ignores this limit
해결 방법
①Check structural parts against the 600psi continuous load limit; ②enlarge the cross-section or change material for long-term load-bearing parts; ③regularly measure creep deformation; after adjustment, take samples continuously to verify the effect, and resume mass production only after confirming stability
핵심 요약
600psi is the red line for PMMA continuous load; structural verification must follow this limit rather than short-term strength; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!