메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Processing Machinery 3 조회수

POM workshop ventilation configuration

문제 현상
The formaldehyde odor in the POM workshop sometimes exceeds the standard, and relying only on opening windows for ventilation gives unstable results
원인 분석
POM processing continuously releases trace amounts of formaldehyde, and natural ventilation fluctuates greatly due to weather and layout; only local exhaust at the machine can stably control the exposure concentration within the 0.75ppm limit
해결 방법
①Configure local exhaust hoods at the machines; ②regularly test and record the workshop formaldehyde concentration; ③strengthen protection under high-release conditions (barrel cleaning); after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
핵심 요약
POM workshop ventilation is an engineering control problem; local exhaust plus regular testing keeps occupational exposure stably within the limit; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
POM;ventilation;formaldehyde;exhaust hood;testing

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI