Material Drying
3 조회수
PPO Junlong MPPO Process Baseline
문제 현상
【Problem Phenomenon】MPPO mold trials lack a starting process baseline, and debugging takes detours
원인 분석
Junlong MPPO series reference: barrel rear 260/middle 270/front 280℃, nozzle 280℃, mold temperature 80-100℃, injection pressure 126MPa, screw 73rpm, drying 90-110℃×3-4h; can be used as a debugging starting point for similar grades
해결 방법
Start from this baseline and fine-tune according to the product; adjust mold temperature within the 80-100℃ range according to defect type; fix the process card after first piece confirmation; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
핵심 요약
MPPO debugging has a baseline parameter table; start with rear 260, front 280, mold temperature 80-100; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!