Material Analysis
11 조회수
PPO Low-Warpage Grades for Precision Parts
문제 현상
[Problem Phenomenon] Warpage of precision structural parts exceeds the standard, and standard PPO grades are difficult to meet the requirements
원인 분석
PPO has low-warpage grades (HS2000 containing 20% filler) designed specifically for warpage-sensitive parts; the low shrinkage of 0.2-0.7% as a basis combined with filler further stabilizes dimensions
해결 방법
Select low-warpage filled grades for warpage-sensitive parts; use mold flow analysis to assist gate design; verify first-article flatness by CMM; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
핵심 요약
PPO low-warpage grades are the answer for precision parts, and HS2000-type grades are optional; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!