Processing Machinery
3 조회수
PPS Dust and Workshop
문제 현상
The PPS processing workshop has an irritating odor, and operators have throat discomfort
원인 분석
High-temperature PPS melt releases trace amounts of sulfur-containing irritating gas; it accumulates when machine head exhaust is insufficient; workshop ventilation and local exhaust are basic occupational health requirements; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based on experience alone
해결 방법
①Configure local exhaust at the machine head; ②Overall workshop ventilation and air exchange; ③Evacuate personnel and strengthen exhaust during degradation accidents; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
핵심 요약
PPS workshop gas management cannot be ignored; local exhaust plus overall ventilation is the standard configuration; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!