메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Material Drying 3 조회수

PSU Barrel Temperature Fails to Reach Setpoint

문제 현상
In PSU processing, the actual barrel temperature fails to reach the set temperature; plasticization is poor; process personnel repeatedly raise the setpoint to no effect.
원인 분석
The drying blower air inlet is too large and carries away heat; heater band power is insufficient or damaged; improper thermocouple position distorts temperature measurement; equipment aging reduces thermal efficiency.; During on-site troubleshooting, verify item by item according to this mechanism, avoiding blindly adjusting the machine based solely on experience
해결 방법
①When the actual barrel temperature fails to reach the setpoint, the blower air inlet can be turned down; ②Check heater bands and thermocouple condition; ③Calibrate with measured temperature; ④Regular maintenance of equipment thermal system.
핵심 요약
PSU high-temperature process places high demands on equipment thermal systems; blower air inlet adjustment is a practical technique; measured temperature exposes the true capability of the equipment.; After confirming effectiveness, solidify the parameters and practices into the work instructions to prevent recurrence
PSU; barrel temperature; blower; heater band; thermocouple; calibration

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI