Molding Process
7 조회수
PTFE Compression Molding Rough Surface and White Spots
문제 현상
The surface of PTFE compression molded products is rough with white spots, the grainy feel is obvious, and both appearance and sealing performance are affected.
원인 분석
Too low preforming pressure makes the bonding between powder particles not tight; insufficient holding pressure time makes pressure transfer insufficient; when the resin particle size is too large beyond the 25~200μm range, the particle gaps cannot be completely eliminated.
해결 방법
①Increase the preforming pressure per unit area; ②Maintain sufficient holding pressure time to allow full pressure transfer; ③Select resin with an average particle size of 25~200μm; ④Load uniformly to avoid local looseness.
핵심 요약
PTFE white spots and roughness are direct evidence of insufficient compaction; particle size specification is a key point of raw material acceptance; holding pressure time is as important as pressure.; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!