메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Processing Machinery 5 조회수

TPU Melt Temperature Actual Measurement

문제 현상
With the same set temperature, product performance differs between batches
원인 분석
The actual melt temperature deviates from the setting, and TPU is sensitive to temperature; when troubleshooting on site, verify item by item according to this mechanism to avoid blindly adjusting the machine based only on experience; this mechanism has been repeatedly verified by industry literature and should be confirmed first during troubleshooting
해결 방법
Regularly measure the actual melt temperature; correct the setting based on actual measurement; record performance correlated with melt temperature; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
핵심 요약
TPU takes the actually measured melt temperature as the process benchmark; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future
TPUmelt temperature actual measurementcorrectionbenchmark

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI