Material Drying 5 조회수

TPU Lab-Scale Drying

문제 현상
The drying effect of laboratory TPU samples is unstable
원인 분석
Small-batch spreading and equipment differences; when troubleshooting on site, verify item by item according to this mechanism to avoid blindly adjusting the machine based only on experience; this mechanism has been repeatedly verified by industry literature and should be confirmed first during troubleshooting
해결 방법
Lab-scale drying in a vacuum oven at 90°C × 3 hours; spread in a thin layer; record the conditions; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
핵심 요약
Standardize lab-scale drying; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future
TPUlab-scalevacuum ovenstandardization