Injection Molding
5 조회수
Low Weld Line Strength in CMC '2079851475616104452
문제 현상
In multi-gate CMC injection molded products, the strength at the weld line is only 30-40% of the whole
원인 분석
The temperature of the two melt fronts has dropped, resulting in small molecular chain diffusion depth and insufficient entanglement; dispersed phase orientation at the weld line is discontinuous
해결 방법
1)Increase injection temperature by 10-15°C to increase diffusion depth; 2)Increase injection speed to keep front temperature high; 3)Increase holding pressure to ensure compaction at the weld; 4)Set an overflow well at the weld line and cut it off afterwards
핵심 요약
Low weld line strength is caused by insufficient molecular entanglement; high-temperature high-speed injection and overflow wells are effective countermeasures
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!