Molds & Tooling
4 조회수
CMC Length Out of Tolerance
문제 현상
Length deviation of CMC products >±0.5mm exceeds the tolerance
원인 분석
CMC shrinkage is unstable, fluctuating ±0.5%; mold dimension design does not consider shrinkage compensation; cooling is insufficient and dimensions are not stabilized
해결 방법
1)Accurately measure CMC shrinkage and compensate the mold; 2)Fully cool to ensure dimensional stability; 3)Annealing treatment to eliminate post-shrinkage
핵심 요약
Length out of tolerance is caused by unstable shrinkage; accurate shrinkage compensation is the key