Material Drying
4 조회수
MP '2079851475616104452 thick-wall bubbles
문제 현상
MP injection molded thick-wall products have dense bubbles 0.1-0.5mm inside, concentrated at the wall thickness center
원인 분석
holding pressure insufficient <40MPa or holding time short, thick-wall center not compacted; raw material contains moisture; injection speed too fast entrains air; mold venting poor
해결 방법
1) increase holding pressure to 60-80MPa; 2) extend holding time to fully compact thick walls; 3) fully dry raw material to moisture <0.02%; 4) add vent grooves or vent pins to the mold; 5) gradually decelerate injection to avoid air entrapment
핵심 요약
thick-wall bubbles are caused by a combination of insufficient holding, moisture and poor venting
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!