Material Analysis
14 조회수
Solution for flame-retardant formulation of calcium-zinc stabilizer in formulation lubrication balance
문제 현상
The calcium-zinc PVC system shows flame-retardant formulation-related abnormalities in the formulation lubrication balance production stage, the pass rate decreases.
원인 분석
The zinc burning characteristic of calcium-zinc stabilizers produces flame-retardant formulation problems under specific working conditions.
해결 방법
From the formulation perspective, increase auxiliary stabilizers, combined with process optimization to solve it.
핵심 요약
The flame-retardant formulation problem of the calcium-zinc system in the formulation lubrication balance stage requires comprehensive solution of formulation and process.
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!