Processing Machinery
4 조회수
Large current fluctuation of linear low-density polyethylene extruder
문제 현상
The ammeter reading of the extruder main motor fluctuates greatly, exceeding the normal range.
Current fluctuation reflects unstable screw torque and may be a precursor of poor plasticization or mechanical failure.
원인 분석
(1) Improper barrel temperature setting; too low temperature in the plasticizing section results in large screw torque
(2) Hard impurities are mixed into the raw material
(3) The screw and barrel are worn and the clearance increases
(4) Uneven feeding, sometimes more and sometimes less
(5) The screen is severely clogged and head resistance is large
해결 방법
(1) Optimize barrel temperature to ensure the plasticizing section temperature is at a reasonable value within the 190-250°C range
(2) Check raw material purity and install a magnetic rack on the hopper
(3) Check screw and barrel wear, and replace if necessary
(4) Ensure continuous and uniform feeding to prevent bridging
(5) Regularly replace the screen to prevent clogging
핵심 요약
Current fluctuation is caused by large plasticizing resistance or equipment problems and needs to be solved from temperature control, raw material purity and equipment maintenance.
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!