Extrusion & Post
7 조회수
Excessive shrinkage rate of general-purpose polyethylene extruded products
문제 현상
The extruded product shrinks significantly in size after cooling, exceeding the tolerance range.
Excessive shrinkage rate causes the product size to be small, affecting fitting and use.
원인 분석
(1)General-purpose polyethylene has high crystallinity, and cooling crystallization causes volume shrinkage
(2)The melt temperature is high, the volume expansion is large, and the shrinkage after cooling is large
(3)The cooling rate is slow, the crystallinity is high, and the shrinkage is large
(4)The haul-off speed is too slow, and the product expands at the die
(5)The raw material grade is improperly selected, and the shrinkage rate is large
해결 방법
(1)Appropriately lower the barrel temperature to the lower value within the range of 160-260°C
(2)Appropriately increase the cooling rate to reduce the crystallinity and reduce shrinkage
(3)Adjust the haul-off speed and appropriately increase the draw ratio
(4)Select a grade with a small shrinkage rate, shrinkage rate 1.5-3.0
(5)Reserve shrinkage margin in mold design
핵심 요약
Excessive shrinkage rate is caused by high crystallinity or high temperature, and needs to be solved by controlling the temperature and cooling rate.
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!