메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Molding Process 5 조회수

Sizing device failure of heat-resistant polyethylene extruder

문제 현상
After sizing, the pipe or profile has large dimensional deviation, and the roundness or cross-sectional shape is unqualified. Sizing device failure leads to reduced product dimensional accuracy.
원인 분석
(1) Vacuum degree of vacuum sizing sleeve insufficient or unevenly distributed (2) Sizing sleeve worn, inner diameter enlarged (3) Cooling water flow insufficient or temperature too high (4) Sizing sleeve not concentric with the die (5) Scale or impurities on sizing sleeve inner wall
해결 방법
(1) Check the vacuum pump and piping to ensure the vacuum degree is stable at 0.04-0.08MPa (2) Check sizing sleeve wear, replace if exceeding tolerance (3) Increase cooling water flow, control water temperature at 15-25°C (4) Adjust the concentricity of sizing sleeve and die (5) Regularly clean the sizing sleeve inner wall to remove scale
핵심 요약
Sizing device failure needs to be solved from the three aspects of vacuum system, cooling system and mold accuracy.
sizing devicevacuum degreesizing sleeve wearcooling watermold concentricity