Extrusion & Post
12 조회수
Random copolymer polypropylene pipe special material (Nordic standard) extruded products excessive shrinkage rate(Variant: Mass Production Scenario)
문제 현상
The extruded product shrinks significantly in size after cooling, exceeding the tolerance range.
Excessive shrinkage makes the product undersized, affecting fit and use.In particular, during continuous mass production, this problem is more prominent and requires key attention.
원인 분석
(1)The random copolymer polypropylene pipe special material (Nordic standard) has high crystallinity, cooling crystallization causes volume shrinkage\
(2)Melt temperature too high, large volume expansion and large shrinkage after cooling\
(3)Cooling rate slow, crystallinity high and shrinkage large\
(4)Haul-off speed too slow, the product expands at the die\
(5)Improper raw material grade selection, shrinkage rate too large\
(6)In continuous mass production, process parameter fluctuations or equipment status changes aggravate this problem
해결 방법
(1)Appropriately lower the barrel temperature to the lower value within the 200-220°C range\
(2)Appropriately speed up the cooling rate, reduce crystallinity to reduce shrinkage\
(3)Adjust the haul-off speed, appropriately increase the draw ratio\
(4)Select grades with small shrinkage rate, shrinkage rate 1.0-1.5\
(5)Reserve shrinkage allowance in mold design\
(6)And establish standardized work instructions, paying special attention to parameter stability in continuous mass production
핵심 요약
Excessive shrinkage rate is caused by high crystallinity or high temperature, and needs to be solved by controlling temperature and cooling rate.Targeted preventive measures need to be taken in different production scenarios.
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!