Extrusion & Post 11 조회수

Ovality of random copolymer polypropylene pipe special material pipes exceeding the standard (Variant: strengthened measures)

문제 현상
The pipe cross-section is not round, and the ovality exceeds the tolerance. Ovality exceeding the standard affects the connection and installation of the pipe, and may cause leakage in socket connections and mechanical connections. In particular, extra attention is needed on the original basis, this problem is more prominent and needs key attention.
원인 분석
(1)The cooling is uneven, and the shrinkage of the pipe in all directions is inconsistent (2)The sizing sleeve is worn or installed incorrectly (3)The clamping force of the haul-off machine is too large, causing the pipe to deform (4)The pipes are improperly stacked and deformed (5)The cooling water temperature is too high, causing the pipe to soften and deform (6)On the original basis, extra attention is needed: process parameter fluctuations or equipment status changes have aggravated this problem
해결 방법
(1)Check the cooling system to ensure uniform cooling of the pipe in all directions (2)Check the sizing sleeve, replace it if worn, and ensure concentric installation (3)Adjust the clamping force of the haul-off machine to avoid being too large (4)Use special storage racks for pipes to avoid stacking deformation (5)Control the cooling water temperature at 15-25°C (6)And strengthen process monitoring; on the original basis, extra attention is needed, with special attention to parameter stability
핵심 요약
Ovality exceeding the standard is caused by uneven cooling or external force deformation, and needs to be solved from cooling uniformity and pipe storage. In different production scenarios, targeted preventive measures need to be taken.
ovality uniform cooling sizing sleeve haul-off clamping pipe storage