메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Extrusion & Post 4 조회수

Cross-linked polyethylene XLPE insufficient crosslinking degree

문제 현상
The crosslinking degree of XLPE products cannot reach the requirement of 60-80%, and the gel content is low. Insufficient crosslinking degree affects the heat resistance and creep resistance of products, and products deform severely at high temperatures.
원인 분석
(1) Peroxide addition insufficient or unevenly dispersed (2) Crosslinking temperature too low or crosslinking time insufficient (3) Peroxide decomposed prematurely (extrusion temperature too high) (4) Irradiation crosslinking dose insufficient (5) Silane crosslinking catalyst activity decreased
해결 방법
(1) Accurately meter peroxide dosage, ensure uniform dispersion (2) Strictly control the crosslinking temperature and crosslinking time window (3) Reduce extrusion temperature to 170-200°C to prevent premature peroxide decomposition (4) Irradiation crosslinking ensures dose rate, total dose meets requirements (5) Silane crosslinking checks catalyst and warm water crosslinking conditions (80-95°C water bath)
핵심 요약
The main cause of insufficient crosslinking degree is insufficient crosslinking agent dosage or improper crosslinking conditions, and strict control is needed from both formulation and process.
crosslinking degreeperoxidegel contentirradiation dosecrosslinking time

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI