Blow Molding
4 조회수
Capacity deviation of PET stretch-blow bottles
문제 현상
The deviation between actual and nominal capacity of PET bottles exceeds ±1.5%, failing to meet filling requirements.
원인 분석
Preform weight deviation causes different capacities after stretching; '2079851475616104457 pressure and mold temperature fluctuate; ambient temperature affects bottle shrinkage.
해결 방법
Control preform weight deviation to ±0.1g; stabilize '2079851475616104457 parameters; test capacity in a constant-temperature environment; regularly calibrate mold dimensions.
핵심 요약
PET bottle capacity accuracy involves dual control of preform weight and the blow '2079851475616104453.