Sorun Belirtisi
ABAK flame retardant modification reaches UL94 V-0, but is affected by flame retardant and compatibility.
Neden Analizi
ABAK flame retardant modification adds brominated/phosphorus flame retardants; compatibility of the flame retardant with the matrix; dispersion uniformity; impact on mechanical properties; processing temperature limitations.
Çözüm
①Select the flame retardant type; ②coordinate the compatibilizer; ③optimize dispersion; ④control temperature; ⑤verify with flame retardant tests.; After adjustment, take consecutive samples to verify the effect, and resume mass production only after confirming stability
Temel Çıkarım
ABAK flame retardant modification is a prerequisite for electronic and electrical applications; compatibility and dispersion are the technologies; testing ensures the rating.; After confirming effectiveness, fix the parameters and practices into the work instructions to prevent recurrence