PA12 Product Ejection Whitening

Sorun Belirtisi
Whitening at ejection positions.
Neden Analizi
Ejection force concentration causes stress whitening; insufficient cooling.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience; This mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Çözüm
①Increase ejection area; ②extend cooling; ③balanced ejection; ④ensure draft angle.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; Change only one variable at a time and record parameter changes to facilitate locating effective measures
Temel Çıkarım
Ejection whitening is a stress signal.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; Include this case in the defect archive as a troubleshooting reference for subsequent similar problems
PA12;ejection whitening;ejection;stress;cooling;draft angle