Processing Machinery 4 görüntüleme

PET material change cleaning temperature

Sorun Belirtisi
After PET is changed to other materials, gel particles and black specks persist for a long time
Neden Analizi
PET has a high melting point, and the residual material requires high temperature to be discharged, so a low-temperature purging material cannot push out the retained PET; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
Çözüm
For material change, first use purging material at 280℃ to push out the PET; then lower the temperature to switch; disassemble and clean the dead corners; after adjustment, take consecutive samples to verify the effect, and resume mass production only after confirming stability
Temel Çıkarım
High-temperature material change requires purging at the same temperature before lowering the temperature; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems